Skip to content
  • QUOTE
  • 888.653.333
  • [email protected]
  • Products
    • Fire Protective Glass Tested to NFPA 252/257, UL 9/10C, ULC S104/S106; Blocks smoke and flames.
    • SuperLite® I
    • SuperClear® 45-HS
    • SuperClear® 45-HS-LI
    • SuperLite® I-XL
    • SuperLite® I-XL IGU
    • SuperLite® X-45/60/90
    • SuperLite® II-XL 45
    • Ceramics
    • Fire Resistive Glass Tested to ASTM E119 / UL 263 / ULC S101; Blocks smoke, flames and radiant heat.
    • SuperLite® II-XL 60
    • SuperLite® II-XL 90
    • SuperLite® II-XL 120
    • SuperLite® II-XLB 60
    • SuperLite® II-XLB 120
    • SuperLite® II-XLM 60
    • SuperLite® II-XLM 120
    • SuperSecure® II-XLS 45-120
    • Fire Rated Walls 60-120 minute fire resistive glass and frame assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® Architectural Series Fire Resistive
    • GPX® Curtain Wall
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Blast System
    • GPX® EZ Frame
    • Fire Rated Doors Full vision 20-45 minute fire protective doors and 60-90 minute temperature rise doors tested to NFPA 252 / UL 10C / ULC S104.
    • GPX® Architectural Series Fire Protective
    • GPX® Architectural Series Fire Resistive
    • GPX® Builders Series Fire Protective
    • GPX® Builders Series Temperature Rise
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Vision Kit
    • Fire Rated Openings 20-45 minute fire protective glass and framing assemblies tested to NFPA 257 / UL 9 / ULC S106.
    • GPX® Architectural Series Fire Protective
    • GPX® Builders Series Fire Protective
    • GPX® EZ Frame
    • Fire Rated Floors 60-120 minute fire resistive glass floor assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® FireFloor
    • Fire Rated Fences 20-60 minute fire rated glass fence for WUI areas or designated fire zones.
    • SAFTI FENCE
  • Literature
  • Specs
  • Details
  • Learn
    About Us
    Videos
    Case Studies
    Articles
    Blogs
    Continuing Education
    Literature
    BIM Library
    Industry Links
    Press Releases
    Testimonials
    Technical Bulletins
    Newsletters
    Product Selector
  • Gallery
  • Reps
  • Contact
  • Products
    • Applications
    • Fire Protective Glass
    • Fire Rated Doors
    • Fire Rated Fences
    • Fire Resistive Glass
    • Fire Rated Floors
    • Fire Rated Openings
    • Fire Rated Walls
    • W-30
  • Literature
  • Specs
  • Details
  • Learn
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Reps
  • Contact
Menu
  • Products
    • Applications
    • Fire Protective Glass
    • Fire Rated Doors
    • Fire Rated Fences
    • Fire Resistive Glass
    • Fire Rated Floors
    • Fire Rated Openings
    • Fire Rated Walls
    • W-30
  • Literature
  • Specs
  • Details
  • Learn
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Reps
  • Contact
Articles
CODE EDUCATION
The Truth About 60 minute Fire Rated Glass
CODE EDUCATION

The Truth About 60 minute Fire Rated Glass

ByDiana S
| October 7, 2014

Facts and Fictions of 60 Minute Fire Rated Glass

The Truth About 60 minute Fire Rated Glass. There is a lot of confusion about what type of fire rated glass to use in 60 minute applications. This article sorts Fact from fiction related to 60 minute fire rated glass applications.

FICTION: 60-minute windows are accepted for use to protect openings as provided by codes.

FACT: There is no such thing as a 60-minute window under building codes, which uniformly limit windows to applications rated 45-minutes or less.

FICTION: 60-minute fire-rated glazing tested and listed for use in windows, sidelights and transoms are permitted by codes when used in accordance with their listings.

FACT: For glazing to be rated for use in 60-minute assemblies, it must be tested to the wall test criteria under ASTM E119 including temperature rise limits.

FICTION: Glazing tested and listed for use in approved 60-minute rated transom and sidelight assemblies are allowed by codes in sizes specified in their listings.

FACT: Fire-rated glazing is permitted in sidelight and transom frames rated 45-minutes or less. For acceptance in 60-minute frames, glazing must meet ASTM E119 criteria, and be tested for use under door test standards.

FICTION: Where 45-minute rated is required, 60-minute rated glazing is better.

FACT: The extra fifteen minutes of fire endurance is not a benefit, says the former NFPA 80 Chairman, because during that time uncontrolled transfer of radiant heat can ignite combustibles on the other side and actually spread fire rather than contain it. CSFM withdrew its listing of FireLite in 60-minute window applications, and now only approves 45-minute window uses to 1296sq. inches, and limits use to 100 sq. inches in 60/90-minute doors.

Share:
PrevNext ArticleA History of Codes on 60 minute fire rated glass
Previous ArticleCode Tips 60 minute Fire Rated GlassNext
Back to Articles

Engineering. Design. Code.

Whether you’re looking for fire-rated walls, doors, openings, floors or a specialty service, we have the solution for you. With over 40 years of experience in testing, innovating, and providing technologically advanced fire-rated glass and framing products, we deliver unyielding performance and quality at a competitive price.

Let's Talk!

  • 888.653.3333
    (English)
  • 888.653.3333 ext. 652
    (Spanish)
  • [email protected]
  • Representative Map
Address
Corporate
100 N Hill Dr, Ste12, Brisbane, CA 94005
Factory
220 S R Street, Merced, CA 95341
Contact
Phone
888.653.3333 - English
888.653.3333 ext. 652 - Spanish
Fax
888.653.4444
Email
[email protected]

Sign up for our Newsletter!

Get notified of industry updates and new product alerts.

© [year] SAFTI FIRST. All rights reserved.​
Disclaimer & Privacy Policy | Cookie Policy
Instagram Twitter Linkedin Facebook Youtube Vimeo
Suggested Pages
Case Studies
Videos Archive
Request a Quote
SuperClear® 45-HS-LI
Continuing Education
Request a Quote
Continuing Education
Videos
SuperClear® 45-HS-LI
Case Studies