Skip to content
  • QUOTE
  • 888.653.333
  • [email protected]
  • Products
    • Fire Protective Glass Tested to NFPA 252/257, UL 9/10C, ULC S104/S106; Blocks smoke and flames.
    • SuperLite® I
    • SuperClear® 45-HS
    • SuperClear® 45-HS-LI
    • SuperLite® I-XL
    • SuperLite® I-XL IGU
    • SuperLite® X-45/60/90
    • SuperLite® II-XL 45
    • Ceramics
    • Fire Resistive Glass Tested to ASTM E119 / UL 263 / ULC S101; Blocks smoke, flames and radiant heat.
    • SuperLite® II-XL 60
    • SuperLite® II-XL 90
    • SuperLite® II-XL 120
    • SuperLite® II-XLB 60
    • SuperLite® II-XLB 120
    • SuperLite® II-XLM 60
    • SuperLite® II-XLM 120
    • SuperSecure® II-XLS 45-120
    • Fire Rated Walls 60-120 minute fire resistive glass and frame assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® Architectural Series Fire Resistive
    • GPX® Curtain Wall
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Blast System
    • GPX® EZ Frame
    • Fire Rated Doors Full vision 20-45 minute fire protective doors and 60-90 minute temperature rise doors tested to NFPA 252 / UL 10C / ULC S104.
    • GPX® Architectural Series Fire Protective
    • GPX® Architectural Series Fire Resistive
    • GPX® Builders Series Fire Protective
    • GPX® Builders Series Temperature Rise
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Vision Kit
    • Fire Rated Openings 20-45 minute fire protective glass and framing assemblies tested to NFPA 257 / UL 9 / ULC S106.
    • GPX® Architectural Series Fire Protective
    • GPX® Builders Series Fire Protective
    • GPX® EZ Frame
    • Fire Rated Floors 60-120 minute fire resistive glass floor assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® FireFloor
    • Fire Rated Fences 20-60 minute fire rated glass fence for WUI areas or designated fire zones.
    • SAFTI FENCE
  • Literature
  • Specs
  • Details
  • Learn
    About Us
    Videos
    Case Studies
    Articles
    Blogs
    Continuing Education
    Literature
    BIM Library
    Industry Links
    Press Releases
    Testimonials
    Technical Bulletins
    Newsletters
    Product Selector
  • Gallery
  • Reps
  • Contact
  • Products
    • Applications
    • Fire Protective Glass
    • Fire Rated Doors
    • Fire Rated Fences
    • Fire Resistive Glass
    • Fire Rated Floors
    • Fire Rated Openings
    • Fire Rated Walls
    • W-30
  • Literature
  • Specs
  • Details
  • Learn
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Reps
  • Contact
Menu
  • Products
    • Applications
    • Fire Protective Glass
    • Fire Rated Doors
    • Fire Rated Fences
    • Fire Resistive Glass
    • Fire Rated Floors
    • Fire Rated Openings
    • Fire Rated Walls
    • W-30
  • Literature
  • Specs
  • Details
  • Learn
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Reps
  • Contact
Articles
CODE EDUCATION
FAQ Fire Rated Framing Code Requirements
CODE EDUCATION

FAQ Fire Rated Framing Code Requirements

ByDiana S
| November 26, 2014

FAQ Fire Rated Framing Code Requirements

FAQ Fire Rated Framing Code Requirements. Now that you’ve figured out which kind of fire rated glass should be used to comply with the codes, don’t forget that the codes are also specific about the type of framing required.

What are the code requirements for fire rated framing?

Because fire rated glazing is used in door, window and wall assemblies, code requirements for framing must also be considered. Simply put, the fire rated framing requirements must match the glazing requirements in order for the assembly to fully meet the requirements of the code. Fire protective framing is allowed where codes allow fire protective glazing. When codes require fire resistive glazing to block radiant heat transmission, fire resistive framing must be used, and the entire assembly must meet the same rating requirement as the wall.

For example, project specifications that configure fire resistive glazing in hollow metal frames in 1-or 2-hour exit enclosure applications fail to meet code, because fire resistive glazing with fire protective framing lowers the overall fire performance rating of the assembly to fire protective. In 1-or 2-hour applications where meeting ASTM E-119/NFPA 251/UL 263 is required, both the glazing and the framing must be fire resistive.

Fire Protective Framing

The most common frame is hollow metal, such as GPX Builders Series Fire Protective. Hollow metal frames are fire protective, not fire resistive, and they fail to block the spread of radiant heat. Fire protective framing, like fire protective glazing, has limited use in applications rated over 45 minutes. This type of framing can be used in doors, sidelites, transoms and interior windows up to 45 minutes.

 

Hollow metal section Hot rolled steel section
FAQ Fire Rated Framing Code Requirements
Fire Protective Framing

 

Fire Resistive Framing

When the code requires fire resistive glazing, it must be part of an equally rated framing system. Fire resistive framing, such as GPX Architectural Series Framing, has the ability to block the spread of radiant heat. Like fire resistive glazing, this type of framing meets ASTM E-119/NFPA 251/UL 263 requirements. Fire resistive framing can be used in wall and door assemblies (this includes glazing around and over the door, such as sidelites and transoms) rated 60 minutes and above.

 

FAQ Fire Rated Framing Code Requirements

 

Got questions on fire rated glass and framing? Train with a recognized code expert while earning 1 AIA LU and 1 HSW credit with our AIA-accredited webinar program “Designing with Fire Rated Glass.”

To schedule a free webinar for your firm, send an email to [email protected]. For more information on SAFTI FIRST’s products, please visit www.safti.com.

Share:
PrevNext Article60 minute Fire Rated Glass Applications
Previous ArticleFAQ Fire Rated Glass in Sidelites and TransomsNext
Back to Articles

Engineering. Design. Code.

Whether you’re looking for fire-rated walls, doors, openings, floors or a specialty service, we have the solution for you. With over 40 years of experience in testing, innovating, and providing technologically advanced fire-rated glass and framing products, we deliver unyielding performance and quality at a competitive price.

Let's Talk!

  • 888.653.3333
    (English)
  • 888.653.3333 ext. 652
    (Spanish)
  • [email protected]
  • Representative Map
Address
Corporate
100 N Hill Dr, Ste12, Brisbane, CA 94005
Factory
220 S R Street, Merced, CA 95341
Contact
Phone
888.653.3333 - English
888.653.3333 ext. 652 - Spanish
Fax
888.653.4444
Email
[email protected]

Sign up for our Newsletter!

Get notified of industry updates and new product alerts.

© [year] SAFTI FIRST. All rights reserved.​
Disclaimer & Privacy Policy | Cookie Policy
Instagram Twitter Linkedin Facebook Youtube Vimeo
Suggested Pages
Case Studies
Videos Archive
Request a Quote
SuperClear® 45-HS-LI
Continuing Education
Request a Quote
Continuing Education
Videos
SuperClear® 45-HS-LI
Case Studies